Code Alarm SRT 1600 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Elektronika motorových vozidel Code Alarm SRT 1600. Code Alarm SRT 1600 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 25
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Digital Temperature Controller E5CN
Compact and Intelligent Temperature
Controller
Auto-tuning and self-tuning available.
Can auto-tune even during execution of
self-tuning
Heating or heating/cooling control is
available
Event input allows multiple SP selection
and run/stop function
Water-resistant construction: NEMA4
(equivalent to IP66)
Various temperature inputs:
thermocouple, platinum resistance
thermometer, non-contact temperature
sensor, and analog inputs
Conforms to UL, CSA, IEC, and CE
Ordering Information
E5CN STANDARD MODELS
Description Part number
Size Power supply
voltage
No. of
alarm
points
Output Thermocouple model Platinum resistance
thermometer model
1/16 DIN
4
8
(
W
)
4
8
(
H
)
100 to 240 VAC ---
Relay E5CN-RMTC-500 AC100-240 E5CN-RMP-500 AC100-240
48(W) x 48(H) x
78(D) mm
Voltage output
(for driving SSR)
E5CN-QMTC-500 AC100-240 E5CN-QMP-500 AC100-240
2
Relay E5CN-R2MTC-500 AC100-240 E5CN-R2MP-500 AC100-240
Voltage output
(for driving SSR)
E5CN-Q2MTC-500 AC100-240 E5CN-Q2MP-500 AC100-240
24 VAC/VDC ---
Relay E5CN-RMTC-500 AC/DC24 E5CN-RMP-500 AC/DC24
Voltage output
(for driving SSR)
E5CN-QMTC-500 AC/DC24 E5CN-QMP-500 AC/DC24
2
Relay E5CN-R2MTC-500 AC/DC24 E5CN-R2MP-500 AC/DC24
Voltage output
(for driving SSR)
E5CN-Q2MTC-500 AC/DC24 E5CN-Q2MP-500 AC/DC24
Note: 1. The suffix “500” is added to the part number of each Controller provided with a E53-COV10 Terminal Cover.
2. The heating and cooling function is available for models with two alarm points.
Zobrazit stránku 0
1 2 3 4 5 6 ... 24 25

Shrnutí obsahu

Strany 1 - Ordering Information

Digital Temperature Controller E5CNCompact and Intelligent TemperatureControllerAuto-tuning and self-tuning available.Can auto-tune even during execu

Strany 2 - ACCESSORIES

E5CNE5CNSpecification Setting After Turning ON PowerOUTLINE OF OPERATION PROCEDURESKey OperationIn the following descriptions, all the parameters are

Strany 3 - INPUT RANGES

E5CNE5CNCommunications Setting LevelTo select this level, press the key once for less than onesecond in the initial setting level. When the communicat

Strany 4 - Specifications

E5CNE5CNSPECIFICATION SETTING (AFTERTURNING ON POWER)Initial Setting LevelThis level is used for setting basic specifications of theTemperature Contro

Strany 5 - CHARACTERISTICS

E5CNE5CNINPUT TYPEUsing a Thermocouple Input TypeWhen using a thermocouple input type, follow the specifications listed in the following table.Input t

Strany 6 - COMMUNICATIONS SPECIFICATIONS

E5CNE5CNALARM 1 AND ALARM 2For the alarm 1 and alarm 2, select alarm types out of the 12 alarm types listed in the following table.Set ValueAlarm Type

Strany 7 - Nomenclature

E5CNE5CNPARAMETERSParameters related to setting items for each level are marked inboxes in the flowcharts and brief descriptions are given asrequired.

Strany 8 - Operation

E5CNE5CNInitial Setting LevelInput typeScaling upper limitDecimal pointTemperature unitSet point upper limitPID / ON/OFFStandard/heating and coolingST

Strany 9

E5CNE5CNAdvanced Function Setting LevelParameter initializeAlarm 2 hysteresisAlarm 2 open in alarmAlarm 1 hysteresisAlarm 1 open in alarmStandby seque

Strany 10 - DESCRIPTION OF EACH LEVEL

E5CNE5CNCommunications Setting LevelSet the E5CN/E5GN communications specifications in the communications setting level. For setting communications pa

Strany 11 - Calibration Level

E5CNE5CNTROUBLESHOOTINGWhen an error occurs, an error code will be displayed on the No. 1 display. Check the contents of an error and take appropriate

Strany 12 - TURNING ON POWER)

E5CNE5CNE5CN OPTION BOARDSThe E5CN provides communications or event input functionality when mounted with one of the following Option Boards.ItemFunct

Strany 13 - INPUT TYPE

E5CNE5CNDimensionsUnit: mm (inch)E5CN•Recommended panel thickness is 1 to 5 mm.•Group mounting is not possible in the vertical direction.(Maintain the

Strany 14 - ALARM 1 AND ALARM 2

E5CNE5CNCURRENT TRANSFORMER (SOLD SEPARATELY)E54-CT15.8 dia.Two, 3.5 dia.21(0.83)30(1.18)1040(1.57)25(0.98)31510.57.52.8E54-CT312 dia.Two, M3 (depth:

Strany 15 - PARAMETERS

E5CNE5CNInstallationSETTING UP OPTION BOARDSIf communications, event input, or heater burnout functions are required, mount the E53-CNH03 Communicatio

Strany 16 - Adjustment Level

E5CNE5CNWIRING TERMINALSThe voltage output (control output) is not electrically insulatedfrom the internal circuits. When using a grounding thermocoup

Strany 17

E5CNE5CNPrecautionsOPERATING ENVIRONMENT•Use the Temperature Controller within the rated operatingtemperature, storage temperature, and operating humi

Strany 18

E5CNE5CNCat.No.GCTC12 1/99 Specificationssubjecttochangewithoutnotice. PrintedinU.S.A.Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 568139

Strany 19 - Fuzzy Self-tuning

E5CNE5CNINPUT RANGESPlatinum Resistance Thermometer InputTemperature range1800170016001500140013001200110010009008007006005004003002001000--100--200Pt

Strany 20 - Dimensions

E5CNE5CNSpecificationsRATINGSSupply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDCOperating voltage range 85% to 110% of rated supply voltag

Strany 21

E5CNE5CNCHARACTERISTICSIndication accuracy Thermocouple:( 0.5% of indicated value or 1 C, whichever greater) 1 digit max. (See Note.)Platinum resistan

Strany 22 - Installation

E5CNE5CNCOMMUNICATIONS SPECIFICATIONSTransmission path connection Multiple pointsCommunications method RS-485 (two-wire, half duplex)Synchronization m

Strany 23 - WIRING PRECAUTIONS

E5CNE5CNNomenclatureE5CNTemperature UnitThe temperature unit is displayedwhen the display unit parameteris set to a temperature. Indicationis determin

Strany 24 - Precautions

E5CNE5CNOperationINITIAL SETUPOn previous Controllers, sensor input type, alarm type andcontrol period were set on DIP switches. These hardwaresetting

Strany 25

E5CNE5CN2. PID Control Using Auto-tuningTypical Application Example• Changing Parametersindicates that there is a parameter. Keepon pressing the mode

Komentáře k této Příručce

Žádné komentáře