Intrusion Alarm Systems | DS7400Xi Series Addressable Control Panels
DS7400Xi Series Addressable Control
Panels
www.boschsecurity.com
u Up to 248 zones in up to eight areas
u 400-event history buffer
u Up to 200 personal ID numbers (PINs)
u Up to 112 wireless devices
u Up to 15 keypads and/or door access control
modules (DACMs)
The DS7400Xi Series Addressable Control Panels can
be programmed for up to eight areas, are keypad or
remotely programmable, and have a wide range of
features.
Functions
Answering Machine Override
Each control panel model has a built-in answering
machine override function. No external hardware is
required.
Automatic Arming and Delayed Arming
Program an automatic arming time for each area daily.
Use delayed arming to override automatic arm time or
to specify a time for the panel to arm.
Common Area Arming
Program one area to follow the arming state of some
or all of the other areas. The common area arms only
when all areas linked to it are armed, protecting
shared areas such as foyers and entry-ways while
maintaining separate areas.
Custom Arming Configurations
Program the system to arm in different configurations
to automatically bypass a group of zones.
Easy Function Key User Interface
Six labeled function keys eliminate the need for multi-
button commands. Enter a PIN followed by the
function key to perform functions such as arming,
disarming, and resetting smoke detectors.
The interface provides new users with easy to follow
procedures. Expert users can quickly access items.
A programmable Quick Arm feature allows users to
turn the system on without a PIN. The system
requires a PIN to turn off the system, silence alarms,
or perform system tests.
EEPROM Technology
The control panel uses electronically erasable
programmable read-only memory (EEPROM). The
EEPROM retains program memory, system
programming, user codes, and the arm/disarm state
through a power failure. There is a delay on power
restore that prevents false alarms from space sensors
that might take several minutes to become
operational.
Zobrazit stránku 0
1 2 3 4 5

Shrnutí obsahu

Strany 1 -

Intrusion Alarm Systems | DS7400Xi Series Addressable Control PanelsDS7400Xi Series Addressable ControlPanels www.boschsecurity.com u Up

Strany 2

Eight AreasDivide the control panel into eight separate systemareas, each area with its own keypads and reportingID. Keypads can be programmed as mast

Strany 3 - DS7400XI-EXP

DS7481 Single Phone Line Monitor DS7489 Solid State Output Module DX3010 Octo-output Expander DX4010i RS-232 Serial Interface ModuleMultiplexDete

Strany 4

DS7400XI-BEL Control PanelFor use in Belgium. Includes a large enclosure. Alwayshas 128 points enabled.Order number DS7400XI-BELDS7400XI-CHI Control P

Strany 5

5 | DS7400Xi Series Addressable Control PanelsRepresented by:Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:Bosch Security

Komentáře k této Příručce

Žádné komentáře